{"product_id":"dcomp1","title":"Comprehensive Defibrillator Service \u0026 Health Check All Makes \u0026 Models","description":"\u003cp class=\"value\"\u003e\u003c\/p\u003e\u003ch2\u003e\u003cstrong\u003eComprehensive Single Compliance Service to Ensure Your Defibrillation Device is Rescue Ready\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eEnsure your defibrillator is always rescue ready with our comprehensive servicing, performed by highly trained engineers. We offer both annual and one-off service visits to your premises, ensuring your life-saving equipment is always in optimal condition and ready for emergency use.\u003c\/p\u003e\u003ch3\u003eVisual inspection\u003c\/h3\u003e\u003cp\u003eOur engineers will carry out \u003cstrong\u003evisual inspection of the defibrillatorâ€™s case, screen, buttons, and connections\u003c\/strong\u003e, checking for any cracks or damage that could pose infection control risks or impact functionality.\u003cbr\u003e\u003cbr\u003e Identify andÂ record any \u003cstrong\u003esigns of deterioration\u003c\/strong\u003eÂ or parts that may require replacement.\u003cbr\u003e\u003cbr\u003e Check and record the\u003cstrong\u003e pads' expiration dates\u003c\/strong\u003e, ensuring they are within the valid date range.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003eECG and defibrillator tests using simulators to confirm accuracy\u003c\/h3\u003e\u003cp\u003eThe engineers will \u003cstrong\u003etest the patient monitor\u003c\/strong\u003e by connecting it to a patient simulator using ECG leads and defibrillator test leads, simulating both normal sinus rhythm and ventricular fibrillation to check the defibrillatorâ€™s response.\u003c\/p\u003e\u003cp\u003eTest the\u003cstrong\u003eÂ energy output\u003c\/strong\u003eÂ of the defibrillator at specific energy points, ensuring it is within the required tolerance levels.\u003c\/p\u003e\u003cp\u003eVerify that theÂ \u003cstrong\u003eshock outputÂ energy levels\u003c\/strong\u003e are within acceptable ranges.\u003c\/p\u003e\u003cp\u003eCheck \u003cstrong\u003epacer function\u003c\/strong\u003eÂ (if available) following service manual guidelines.\u003c\/p\u003e\u003cp\u003eCheck all \u003cstrong\u003emonitor leads\u003c\/strong\u003eÂ and acquire printouts (if applicable) to verify accuracy and sensitivity.\u003c\/p\u003e\u003cp\u003eFor devices with additional functions, check theÂ NIBP systemÂ for leaks and accuracy at various pressure points, ensuring it \u003cstrong\u003emeets specified standards\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpO2 accuracy\u003c\/strong\u003eÂ is tested using a simulator at multiple levels, confirming it stays within acceptable limits.\u003c\/p\u003e\u003cp\u003eVerify that theÂ \u003cstrong\u003esync time\u003c\/strong\u003eÂ (if applicable) is within manufacturer specifications.\u003c\/p\u003e\u003cp\u003eIf applicable, \u003cstrong\u003erun aÂ self-test\u003c\/strong\u003eÂ to ensure the device passes all internal diagnostics.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003eSafety tests for electrical connections and battery health\u003c\/h3\u003e\u003cp\u003eSwitch on the device and test its overall functionality to \u003cstrong\u003eensure it's operational\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eConfirm the defibrillator isÂ suitable for its intended purpose, ensuring it's \u003cstrong\u003ecompliant and ready for use\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eRecord theÂ \u003cstrong\u003ebattery level\u003c\/strong\u003eÂ or verify that the device does not require a battery replacement.\u003c\/p\u003e\u003cp\u003eInspect for any \u003cstrong\u003eloose electrical connections\u003c\/strong\u003e that could affect performance.\u003c\/p\u003e\u003cp\u003ePerform an \u003cstrong\u003eelectrical safety test\u003c\/strong\u003e in compliance with IEC 62353 standards.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003eDetailed recording of device information and any required repairs\u003c\/h3\u003e\u003cp\u003eRecord the make, model, and serial number using a PDA, creating aÂ \u003cstrong\u003edetailed logÂ for future reference\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eAssign a \u003cstrong\u003eunique ID number\u003c\/strong\u003e and barcode to the defibrillator for easy tracking throughout its lifecycle.\u003c\/p\u003e\u003cp\u003eOnce testing is complete, ensure the defibrillator is labelled appropriately as either a pass or fail, and notify your site contact of any failed checks or issues that need addressing.\u003c\/p\u003e\u003cp\u003eAt the end of each service, we provide you with a detailed report, outlining all findings, recommended repairs, and confirming whether the equipment is suitable for continued use. This \u003cstrong\u003eensures full compliance with safety regulations\u003c\/strong\u003e and gives you the confidence that your defibrillator will perform reliably when needed most.\u003c\/p\u003e\u003cp\u003eStay compliant, stay prepared with our expert defibrillator servicing.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNot suitable for single use devices\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Rejuv Direct","offers":[{"title":"Default Title","offer_id":56359994360182,"sku":"DCOMP1","price":198.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0924\/6549\/6438\/files\/defib_servicing_2_59f7f95d-12aa-42b2-8313-48ce211a1d5b.jpg?v=1759080540","url":"https:\/\/rejuvdirect.store\/products\/dcomp1","provider":"Rejuv Direct","version":"1.0","type":"link"}