Description
IPAD SP1 AED Fully Automatic Defibrillator
Designed for minimally trained individuals to use in the workplace, schools, shopping centre or a hospital.
One of the unique features to the SP1 is that you can easily switch switch to paediatric mode by simply lifting a clear, safety cover on the front. The pre connected dual electrode pads can be used on both adults and children, saving valuable time and and anxiety in an emergency situation. This unit has an ambient noise detector, where in a noisy environment the voice prompts will automatically increase so the individual working the unit can hear the instructions.
In the Box
1 x IPADÂ SP1 Fully-automatic Defibrillator with up to 10 Year Guarantee
1 x Soft Carry Case to help protect your IPADÂ SP1 and hold your essential rescue items
1 x Set of Electrode PadsÂ
1 x Disposable Lithium Manganese Oxide Battery with 4 Year Warranty
1 x AED rescue kits, which include
     2 x Patient Wipes
     1 x Pair of Nitrile Gloves
     1 x Prep Razor
     1 x Face Shield
     1 x Pair of Tough Cut Scissors
1 x IPADÂ SP1 set up guide
Â
Exclusive Extras from
    FREE Replacement Pads if this device is used in a rescue within one year
    FREE Email expiry reminders for your Electrode Pads & Battery
    FREE Delivery to Mainland UKÂ
Â
The pads are stored in a clear compartment on the underside of the unit and pre-connected to the defibrillator, making the pads always ready to use and prevent any time consuming incidents that may occur. Comes with 7 year warranty, however plus an additional 3 years if the unit is registered.
Â
- CLEAR AND USER FRIENDLY TO OPERATE AND MAINTAIN
Guidance at every step with clear illuminated illustrations, calm voice prompts & large responsive buttons.
- SIMPLE SWITCH SELECTION FROM ADULT TO CHILD MODE
The same set of electrode pads for both adults and children. Â No additional pads required, Â saving precious time and expense.
-
PRE-CONNECTED ADULT/CHILD “SMART†ELECTRODE PADS
Pad indicator displays illustrates pad life remaining, with verbal instructions to “replace pads†or to “connect padsâ€.
Â
IPAD SP1 FULLY AUTOMATIC AND SEMI-AUTOMATIC DEFIBRILLATORS
| Device Specifications – Model Name: CU-SP1 |
| Physical |
| Category | Nominal Specifications |
| Dimensions | 260mm x 256mm x 69.5mm (Width x Length x Height) |
| Weight | 2.4kg (Including the battery pack and pads) |
| Â | Â |
| Environmental |
| Category | Nominal Specifications |
| Operational Status |
(The device is in emergency use) Temperature: 0°C ~ 43°C (32°F ~ 109°F) Humidity: 5% ~ 95% (non condensing)
|
| Standby Status |
(The device is stored together with the defibrillator pads and the battery pack is inserted ready to be used in an emergency) Temperature: 0°C~ 43°C (32°F ~ 109°F) Humidity: 5% ~ 95% (non condensing)
|
| Altitude | 0 to 15,000 feet (operational and storage) |
| Drop Withstands | 1.2-meter drop to any edge, corner, or surface |
| Vibration |
Operating: Meets MIL-STD-810G Fig.514.6E-1, random Standby: Meets MIL-STD-810G Fig.514.6E-2, swept sine (helicopter)
|
| Sealing | IEC 60529: IP55 |
| ESD | Meets IEC 61000-4-2:2001 |
| EMI (Radiated) | Meets IEC 60601-1-2 limits, method EN 55011:2007 +A2:2007, Group 1, Class B |
| EMI (Immunity) | Meets IEC 60601-1-2 limits, method EN 61000-4-3:2006 +A1:2008 Level 3 (10V/m 80MHz to 2500MHz) |
| Â | Â |
| Defibrillator |
| Category | Nominal Specifications |
| Operating Mode | Fully-automatic or Semi-automated |
| Waveform | e-cube biphasic (Truncated exponential type) |
| Output Energy |
150 J at 50 Ω  load for adults 50 J at 50 Ω load for children
|
| Charge Control | Controlled by an automated patient analysis system |
| Energy Storage | 10 seconds, typical. Using new disposable LiMnO2 battery pack (at 20°C) |
| Charging Time | 11 seconds, typical. Using new disposable LiMnO2 battery pack, depleted by 15 discharges at 200 Joules per discharge (at 20°C) |
| Time from CPR to Shock | Less than 6 seconds from the completion of CPR to shock delivery |
| Discharge |
The device performs a self-discharge in the following events: When the patients ECG changes to a rhythm that does not require defibrillation. When the device is turned off by pressing the Power Button for at least a second. When the pad is detached from the patients body or the pad connector is detached from the device. When the impedance of the patient is out of the range of defibrillation (25 Ω ~ 175 Ω) (Semi-automatic only) When the shock button is not pressed within 15 seconds from the completion of the charge.
|
| Fully-Automatic Shock | Shock is automatically delivered if a shockable rhythm is detected |
Â
![iPAD AED]()
Â
See our full range of , and accessories we sell at . You can also browse our full range of , which are also in stock and ready for quick dispatch.